(+612) 2531 5600
info@medzin.com
PO Box 1622 Colins Street West Victoria 8077 Australia
• Swirl Clinical Centrifuge is used for separation of serum, plasma, urea, urine, blood samples and other routine applications
in hospital and research. They are also used in environmental analyses for clarification of water and soil samples and in
schools as a teaching aid.
• Swirl Clinical Centrifuge has a large ergonomic design with easy to read display and sound alert.
• Automatic lid opening when run is complete prevents sample warming and allow easy access of samples.
• Both RPM and G-force can be displayed.
SKU | Product Type | Product | No. Per Case/Bag | Stock | Price | Quantity | Add to Cart |
---|---|---|---|---|---|---|---|
E11540 | Swirl Clinical Centrifuge | Swirl Clinical Clinical Centrifuge with 8 Place Rotor for 15 ml & 12 Place Rotor for 5, 7 & 10 ml centrifuge tube & Rotor Adapter for 10 ml centrifuge tube | 1 | In stock |
| ||
E11541 | Spare Accessories | 8 Place Rotor for 15 ml & 12 Place Rotor for 5, 7 & 10 ml | 1 | In stock |
| ||
E11542 | Spare Accessories | Rotor Adapter for 10 ml used with E11541 | 12 | In stock |
|
• Swirl Clinical Centrifuge is used for separation of serum, plasma, urea, urine, blood samples and other routine applications
in hospital and research. They are also used in environmental analyses for clarification of water and soil samples and in
schools as a teaching aid.
• Swirl Clinical Centrifuge has a large ergonomic design with easy to read display and sound alert.
• Automatic lid opening when run is complete prevents sample warming and allow easy access of samples.
• Both RPM and G-force can be displayed.
• Digital LCD display can show real time parameters and has symbol showing experimental process.
• Swirl Clinical is used for quick spins by pressing and holding the pulse key.
• It has precise control, high accuracy of speed and has gentle breaking at low speeds with efficient separation.
• Swirl Clinical conforms to international safety standards and regulations. It has also passed the explosion proof test from CE,
TUV and FCC.
• Bio-safe rotor and anti-sample overflow prevents sample leakage in the centrifugal process causing microbial
contamination.
• Swirl Clinical adapts a Brushless DC Motor.
• Passed EN61010-2-101:2002 for invitro diagnostic (IVD) medical equipment.
• Goes into a self-diagnostic check when switched on and then displays accumulative time & last running parameter.
CE certified | Yes |
Voltage | 220-240 V |
Frequency | 50-60 Hz |
Current | 3 A |
Max Speed | 300-4500 rpm with increment of 100 rpm |
Max. RCF [xg] | 2490 xg with increment of 100 xg |
Speed Accuracy | ±20 rpm |
Rotor Capacity | 5 mL/7 mL/10 mL x 12 places. 15 mL x 8 places |
Run Time | 30sec-99min-HOLD (Continuous operation) |
Driving Motor | Brushless DC motor |
Safety Devices | Dual door interlock Over-speed detection Over temperature detection Automatic internal diagnosis |
Noise Level | ≤56 dB |
Additional Features | Speed/RCF switch Short-time run function Sound-alert function |
Dimensions | 301 x 354 x 217 mm |
Acceleration /Braking time | 20 sec for both Acceleration & Breaking |
Weight | 6 kg |
Permissible Ambient Temperature | +4 to +40°C |
Permissible Relative Humidity | 80% |